MIA Toolbox Review Results

From Eigenvector Research Documentation Wiki
Revision as of 18:22, 12 May 2017 by imported>Scott
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Previous Topic: Building Models with Image Data

(Click to Enlarge)

After a model has been built, the results window is updated and several buttons on the Analysis Flowchart are activated. In this example, the model has been built with 4 principal components and we're ready to look at results.

When working with images in MIA_Toolbox, data is actually stored "unfolded" so numerical methods can properly calculate results. However, when results are display the data are "folded" back up when appropriate. Click the ImageGUI button to see a quick display of scores on the first 3 PCs.

(Click to Enlarge)

The ImageGUI is a PCA model exploring interface. It allows you to select areas in the image and or in scatter plots of the first 3 PCs. In the image to the right we are able to see where a feature within the image lies in the scores space.

If you need to explore more than the first 3 PCs the ImageGUI functionality can be recreated using subplots within PlotGUI.

(Click to Enlarge)

Opening a standard Scores plot shows Q vs T2, PC 1 vs PC 2, and a "folded" scores image. We can select a region high in T2 on the Q vs T2 plot and see where those points lie in our folded image. Click the Select button in the Plot Controls and select a region high in T2. These points will be highlighted in the other plots.

(Click to Enlarge)

Double-clicking on that scores image will open it in a new window where you can explore it using the Plot Controls. By selecting PC 2 you can see that it captures the narrow feature in the image. Images may be displayed in false-color and can be adjusted via the Plot Controls.


Next Topic: Applying a Model